The Haier Hydro All-In-One R290 12 kW 200 liters – Three-Phase features an indoor module with a DHW storage tank and a high-performance outdoor unit with R290 refrigerant. It provides year-round comfort, capable of producing water up to 80 °C without electric resistance and stable operation even at −25 °C.
Set Composition
- Indoor unit: HU162F20AHYAE3 with a 200-liter tank (duplex stainless steel 2205).
- Outdoor unit: AW12NHVGHA with DC Inverter Twin Rotary compressor and R290 refrigerant.
Functions and Control
- 2-zone control for circuits with different water temperatures.
- Climate curves with automatic adjustment based on outdoor temperature.
- Automatic mode (cooling/heating) according to indoor demand.
- Smart Grid with power modulation based on grid signal.
- Solar thermal and DHW integration in the indoor module.
- Pool function for water temperature control.
- Automatic antifreeze protection.
Performance (12 kW 3 Ph)
- Heating 35 °C / 7 °C: 12.00 kW · Input 2.35 kW · COP 5.10.
- Heating 55 °C / 7 °C: 11.50 kW · Input 3.48 kW · COP 3.30.
- Cooling 18 °C / 35 °C: 11.50 kW · Input 2.56 kW · EER 4.50.
- Cooling 7 °C / 35 °C: 10.00 kW · Input 2.99 kW · EER 3.35.
- Outdoor operation ranges: heating −25~35 °C · cooling 10~48 °C · DHW −25~43 °C.
Integrated DHW
- Volume: 200 liters · duplex stainless steel 2205.
- Load profile: L · DHW COP 3.10.
- Storage temperature: 25~75 °C.
- Tank resistance: 3 kW.
Hydraulics and Temperatures
- Heating supply: 20~80 °C.
- Cooling supply: 5~25 °C.
- Hydraulic connections: supply/return R1 · DHW inlet/outlet R3/4.
- Expansion vessel: 8 L · safety valve: 3 bar.
Electrical Supply and Protections
- Outdoor unit (AW12NHVGHA): 380–415 V · 3 Ph · 50 Hz · Imax 10.2 A · recommended circuit breaker 16 A.
- Indoor unit (HU162F20AHYAE3): electronic supply 220–240 V · 1 Ph · 50 Hz · Imax 15.0 A · recommended circuit breaker 20 A.
- Auxiliary electric resistance of the indoor module: 380–415 V · 3 Ph · 50 Hz · 2 + 4 kW (2 steps) · Imax 9.5 A · recommended circuit breaker 16 A.
Refrigerant and Sound Level
- Refrigerant: R290 · charge 1.05 kg (CO₂eq 3.15 t).
- Indoor unit sound level: 42 dB.
- Outdoor unit: pressure 52 dB(A) · power 63 dB.
Dimensions and Weight
- Indoor unit: 1780 × 590 × 590 mm · weight 117 kg (gross 133 kg).
- Outdoor unit: 880 × 1250 × 460 mm · weight 129 kg (gross 155 kg).
- Packaging: indoor 2060 × 695 × 695 mm · outdoor 1112 × 1396 × 630 mm.
Power Selection (Guideline)
Size according to the building’s thermal load:
- 30–40 W/m² (well insulated): approx. 130–160 m².
- 50–60 W/m² (medium insulation): approx. 90–110 m².
- 80–100 W/m² (poor insulation): approx. 60–75 m².
Indicative values: confirm with load calculation and planned emitters.
Main Advantages
- All-in-one: compact installation and reduced assembly time.
- High water temperature (up to 80 °C) without electric backup.
- Solid performance with negative outdoor temperatures.
- Advanced management of zones, solar, and pool.
- Modern and quiet design for three-phase residential use.
Installation and Safety Notes
- Installation by a qualified professional and verification of protections.
- R290 (A3, flammable): comply with regulations and best practices.
- Use compatible antifreeze and properly purge the hydraulic circuit.