Haier Hydro All-In-One R290 8 kW 200 Liter Air Source Heat Pump Set - Single Phase with reference HAEHYDROALLINONER290-8 from the brand HAIER
Haier Hydro All-In-One R290 8 kW 200 Liter Air Source Heat Pump Set - Single Phase with reference HAEHYDROALLINONER290-8 from the brand HAIER
Haier Hydro All-In-One R290 8 kW 200 Liter Air Source Heat Pump Set - Single Phase with reference HAEHYDROALLINONER290-8 from the brand HAIER
HAIER

Haier Hydro All-In-One R290 8 kW 200 Liter Air Source Heat Pump Set - Single Phase

REF
HAEHYDROALLINONER290-8
(0)
Free shipping
6726.01 €
€6,726.01
€10,578.00
Up to -3% for professionals. Discover it.
Haier Hydro All-In-One R290 Heat Pump 8 kW with 200-Liter Tank: High performance, hot water up to 80°C, and reliable operation even at −25°C. Single-phase system, quiet, and compact design.
€67
OFFER
BLACK FRIDAY
Click here
BF2501IE-KITHAEHYDROALLINONER290-8
Buy now and receive it between 1 and December 3
Free shipping
Earn +6,727 Sumis for purchasing this product
More about the product

Information about Haier Hydro All-In-One R290 8 kW 200 Liter Air Source Heat Pump Set - Single Phase

The Haier Hydro All-In-One R290 8 kW 200 liters – Single Phase integrates an indoor unit with a domestic hot water storage tank and an outdoor unit with R290 refrigerant. Its inverter technology delivers maximum efficiency and comfort, with the ability to generate water up to 80 °C without electric resistance and maintain operation even at −25 °C.

Set Composition

  • Indoor unit: HU102F20AHYA with a 200-liter tank made of duplex stainless steel 2205.
  • Outdoor unit: AW082HUGHA with DC Inverter Twin Rotary compressor and R290 refrigerant gas.

Functions and Control

  • 2-zone control for heating or cooling circuits with different temperatures.
  • Climate curves that automatically adjust water temperature according to outdoor conditions.
  • Automatic mode that switches between heating and cooling based on ambient temperature.
  • Smart Grid with dynamic power adjustment based on electrical signal.
  • Solar thermal integration to optimize DHW heating.
  • Pool function with water temperature management.
  • Automatic antifreeze protection for the hydraulic circuit.

Performance (8 kW 1 Ph)

  • Heating 35 °C / 7 °C: 8.00 kW · Input 1.50 kW · COP 5.35.
  • Heating 55 °C / 7 °C: 8.00 kW · Input 2.35 kW · COP 3.40.
  • Cooling 18 °C / 35 °C: 7.50 kW · Input 1.58 kW · EER 4.75.
  • Cooling 7 °C / 35 °C: 6.80 kW · Input 1.97 kW · EER 3.45.
  • Outdoor operating ranges: heating −25~35 °C · cooling 10~48 °C · DHW −25~43 °C.

Integrated DHW

  • Volume: 200 liters · duplex stainless steel 2205.
  • Load profile: L · COP 3.13 · Class A+ in DHW heating.
  • Storage temperature: 25~75 °C.
  • Tank resistance: 3 kW.

Hydraulics and Temperatures

  • Heating water: 20~80 °C.
  • Cooling water: 5~25 °C.
  • Hydraulic connections: supply/return R1 · DHW inlet/outlet R3/4.
  • Expansion vessel: 8 L · safety valve 3 bar.

Electrical Data and Protection

  • Power supply: 220–240 V · 1 Ph · 50 Hz.
  • Indoor unit: Imax 14.1 A · recommended circuit breaker 20 A.
  • Outdoor unit: Imax 18.6 A · recommended circuit breaker 20 A.
  • Auxiliary indoor resistance: 1 + 2 kW (2 steps) · Imax 14 A.

Refrigerant and Sound Level

  • Refrigerant: R290 · charge 0.9 kg (CO₂eq 2.7 t).
  • Indoor unit sound level: 40 dB.
  • Outdoor unit: pressure 48 dB(A) · power 59 dB.

Dimensions and Weight

  • Indoor unit: 1780 × 590 × 590 mm · weight 115 kg (gross 131 kg).
  • Outdoor unit: 790 × 1250 × 380 mm · weight 98 kg (gross 121 kg).
  • Packing: indoor 2060 × 695 × 695 mm · outdoor 1022 × 1395 × 550 mm.

Power Selection (Guideline)

Determine according to the building’s thermal load:

  • 30–40 W/m² (well insulated): approx. 100–130 m².
  • 50–60 W/m² (medium insulation): approx. 65–80 m².
  • 80–100 W/m² (poor insulation): approx. 40–50 m².

Indicative values: confirm with load calculation and type of intended emitter.

Main Advantages

  • All-in-one: space-saving and quick installation.
  • Water up to 80 °C without additional electric resistance.
  • High performance in extreme conditions.
  • Smart management of zones, solar thermal, and pool.
  • Elegant, compact, and quiet design for residential or commercial applications.

Installation and Safety Notes

  • Installation by a qualified professional with appropriate protections.
  • R290 (A3, flammable): comply with regulations and best safety practices.
  • Use compatible antifreeze and properly purge the circuit.
Specifications
Manufacturer
HAIER
Reference
HAEHYDROALLINONER290-8
SKU
KITHAEHYDROALLINONER290-8
Included products
AW082HUGHA + HU102F20AHYA
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
VisaMastercardPayPalKlarnaBank transfer
All rights reserved © 2025 GroupSumi