The Haier Hydro All-In-One R290 16 kW 200 liters – Three-Phase combines an indoor unit with a 200-liter DHW tank and a high-capacity outdoor unit with R290 refrigerant. This all-in-one system provides heating, cooling, and domestic hot water in a single unit, delivering water up to 80 °C without electric resistance and ensuring stable performance even at −25 °C.
Set Composition
- Indoor unit: HU162F20AHYAE3 with a 200-liter tank made of duplex stainless steel 2205.
- Outdoor unit: AW16NHVGHA with DC Inverter Twin Rotary compressor and R290 refrigerant.
Functions and Control
- 2-zone control for circuits with different water temperatures.
- Climate curves that adjust output according to outdoor temperature.
- Automatic mode that switches between heating and cooling as needed.
- Smart Grid with power modulation according to electrical signal.
- Integrated solar thermal and DHW management.
- Pool function with precise water temperature control.
- Automatic antifreeze protection for the hydraulic circuit.
Performance (16 kW 3 Ph)
- Heating 35 °C / 7 °C: 16.00 kW · Input 3.23 kW · COP 4.95.
- Heating 55 °C / 7 °C: 15.50 kW · Input 5.08 kW · COP 3.05.
- Cooling 18 °C / 35 °C: 15.50 kW · Input 3.88 kW · EER 4.00.
- Cooling 7 °C / 35 °C: 14.00 kW · Input 4.52 kW · EER 3.10.
- Outdoor operating ranges: heating −25~35 °C · cooling 10~48 °C · DHW −25~43 °C.
Integrated DHW
- Volume: 200 liters · duplex stainless steel 2205.
- Load profile: L · DHW COP 3.10.
- Storage temperature: 25~75 °C.
- Tank resistance: 3 kW.
Hydraulics and Temperatures
- Heating water: 20~80 °C.
- Cooling water: 5~25 °C.
- Hydraulic connections: supply/return R1 · DHW inlet/outlet R3/4.
- Expansion vessel: 8 L · safety valve: 3 bar.
Power Supply and Protections
- Outdoor unit (AW16NHVGHA): 380–415 V · 3 Ph · 50 Hz · Imax 11.6 A · recommended circuit breaker 16 A.
- Indoor unit (HU162F20AHYAE3): 380–415 V · 3 Ph · 50 Hz · Imax 15.0 A · recommended circuit breaker 20 A.
- Auxiliary electric heater: 380–415 V · 3 Ph · 50 Hz · 2 + 4 kW (2 steps) · Imax 9.5 A · recommended circuit breaker 16 A.
Refrigerant and Sound Level
- Refrigerant: R290 · charge 1.25 kg (CO₂eq 3.75 t).
- Indoor unit sound level: 42 dB.
- Outdoor unit: pressure 55 dB(A) · power 66 dB.
Dimensions and Weight
- Indoor unit: 1780 × 590 × 590 mm · weight 117 kg (gross 133 kg).
- Outdoor unit: 880 × 1250 × 460 mm · weight 138 kg (gross 164 kg).
- Packing: indoor 2060 × 695 × 695 mm · outdoor 1112 × 1396 × 630 mm.
Power Selection (Guideline)
Size according to the building's thermal load:
- 30–40 W/m² (well insulated): approx. 180–220 m².
- 50–60 W/m² (medium insulation): approx. 120–150 m².
- 80–100 W/m² (poor insulation): approx. 80–100 m².
Indicative values: confirm by calculating loads and planned emitters.
Main Advantages
- All-in-one: compact installation with reduced space requirements.
- High thermal power to meet large heating and DHW demands.
- Hot water up to 80 °C without electric resistance.
- Stable performance even in extreme cold climates.
- Elegant, robust, and quiet design ideal for large homes or collective installations.
Installation and Safety Notes
- Installation must be carried out by a qualified professional with appropriate electrical protections.
- R290 (A3, flammable): comply with current safety and ventilation regulations.
- Use compatible antifreeze and properly purge the hydraulic circuit.