The Haier GT R290 12 kW (ref. AW122MXGHA) is a high-performance monobloc air-to-water heat pump that combines power, efficiency, and sustainability. Its DC Inverter Twin Rotary technology and use of natural refrigerant R290 allow it to reach up to 80 °C water temperature without auxiliary resistance, ensuring maximum thermal comfort even at –25 °C outdoor temperatures. Ideal for large homes and light commercial applications, this unit offers smart control, A+++ efficiency, and compatibility with solar thermal energy.
Key Features
- Energy class A+++ with SCOP 4.82 (35 °C) / 3.85 (55 °C).
- Extended operating range: heating –25 °C to 35 °C / cooling 10 °C to 48 °C.
- Water temperature up to 80 °C without electric backup (> –15 °C outdoor).
- 2-zone control for independent heating and cooling circuits.
- Climate curves and automatic mode for intelligent adjustment based on ambient temperature.
- DHW + solar thermal management integrated in the standard control.
- Automatic anti-freeze function to protect the hydraulic circuit in winter.
- Smart Grid compatible for power adjustment according to electrical signal.
Energy Performance
- Heating (A7/W35): 12.00 kW · 2.35 kW input · COP 5.10
- Heating (A7/W55): 11.50 kW · 3.48 kW input · COP 3.30
- SCOP 35 °C: 4.82 (A+++) · ηs 190 %
- SCOP 55 °C: 3.85 (A+++) · ηs 151 %
- Cooling (A35/W18): 11.50 kW · 2.56 kW input · EER 4.50
- Cooling (A35/W7): 10.00 kW · 2.99 kW input · EER 3.35
Operating Ranges and Temperatures
- Outdoor: –25 ~ 35 °C (heating) / 10 ~ 48 °C (cooling) / –25 ~ 43 °C (DHW)
- Supply water: 20 ~ 80 °C (heating) / 5 ~ 25 °C (cooling)
- DHW tank: 25 ~ 75 °C
Design, Hydraulics, and Acoustics
- Compressor: 1 × DC Inverter Twin Rotary
- Hydraulic connections: R 1” inlet/outlet
- Expansion vessel: 8 liters integrated
- Sound level: 52 dB(A) pressure / 63 dB power
Refrigerant
- Type: R290 (natural propane)
- Charge: 1.05 kg · CO₂eq 3.15 t
Electrical Data
- Power supply: 220–240 V / 1 / 50 Hz (single-phase)
- Maximum current: 30.6 A · Recommended circuit breaker: 32 A
Dimensions and Weight
- Dimensions (H × W × D): 880 × 1380 × 460 mm
- Net/gross weight: 127 / 165 kg
Included Accessories
- HW-WA101DBT wired controller (standard)
- ATW-A03N PCB box (included)
- Y-Type filter (standard)
Indicative Sizing
Selection should be made according to the building's thermal load. As a guideline, 12 kW can cover approximately:
- Well-insulated buildings (30–40 W/m²): 300–400 m²
- Medium insulation (50–60 W/m²): 200–240 m²
- Poor insulation (80–100 W/m²): 120–150 m²
Indicative values; always confirm by calculating thermal loads according to climate, emitters, and insulation level.