The Haier GT R290 6 kW monobloc air source heat pump (ref. AW062MUGHA) combines heating, cooling, and DHW production in a single outdoor unit. It uses R290 refrigerant (low GWP, zero ozone depletion) and delivers up to 80°C supply temperature without auxiliary resistance when the outdoor temperature is > –15°C, offering a wide operating range and A+++ efficiency.
Key Features
- 2-zone control with independent water temperatures (heating/cooling).
- Climate curves and automatic mode (switches heating/cooling based on room temperature).
- Automatic antifreeze: heats to 15°C if ambient temp < 2°C and water temp < 7°C.
- DHW and solar thermal management for the integrated tank.
- Smart Grid ready: modulation according to utility company signal.
Energy Performance
- Heating (A7/W35): 6.00 kW · input 1.12 kW · COP 5.35
- Heating (A7/W55): 6.00 kW · input 1.82 kW · COP 3.30
- SCOP 35°C: 5.10 (A+++) · ηs 201%
- SCOP 55°C: 3.83 (A+++) · ηs 150%
- Cooling (LWT 18°C / OAT 35°C): 6.00 kW · input 1.20 kW · EER 5.00
- Cooling (LWT 7°C / OAT 35°C): 5.00 kW · input 1.37 kW · EER 3.65
Operating Ranges and Temperatures
- Outdoor heating: –25 ~ 35°C · cooling: 10 ~ 48°C · DHW: –25 ~ 43°C
- Supply water heating: 20 ~ 80°C · cooling: 5 ~ 25°C
- DHW storage (tank): 25 ~ 75°C
Design, Hydraulics, and Acoustics
- Compressor: 1× DC Inverter Twin Rotary.
- Hydraulic connections flow/return: R 1” · Expansion vessel 4.5 liters.
- Sound pressure level: 47 dB(A) · Sound power level: 58 dB.
Refrigerant
- Type: R290 · Charge 0.8 kg · CO₂eq 2.4 t.
Electrical
- Power supply: 220–240 V / 1 / 50 Hz.
- Max. operating current: 13.5 A · Recommended circuit breaker: 16 A.
Dimensions and Weight
- Dimensions (H×W×D): 790 × 1250 × 380 mm.
- Net / gross weight: 94 / 127 kg.
Included Accessories
- Wired controller HW-WA101DBT (standard).
- PCB box ATW-A03N (standard).
- Y-type filter (standard).
Recommended Sizing (indicative by thermal load)
Always select by load calculation. As a guideline, 6 kW covers approximately:
- 30–40 W/m² (well insulated): 150–200 m²
- 50–60 W/m² (medium insulation): 100–120 m²
- 80–100 W/m² (poor insulation): 60–75 m²
Indicative values; confirm according to climate, emitters, and supply temperature.