Acti9 iCV40 RCBO 1P+N C 16 A 30mA ASI with reference A9DF3616 from the brand SCHNEIDER ELECTRIC
Acti9 iCV40 RCBO 1P+N C 16 A 30mA ASI with reference A9DF3616 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

Acti9 iCV40 RCBO 1P+N C 16 A 30mA ASI

REF
A9DF3616
(0)
+110
134.50 €
€134.50
€633.43
If you are a professional, you have an exclusive price. Discover it.
The Schneider Electric Acti9 iCV40 1P+N residual current circuit breaker, 16 A and 30mA, protects against short circuits and overcurrents. It includes type A-SI residual protection and VisiTrip function for quick fault identification.
  • Type A-SI earth leakage protection
  • Breaking capacity of 6000 A at 230 VAC
  • VisiTrip indicators for quick intervention
Buy now and receive it between 7 and 8 April
Express delivery
More about the product

Information about Acti9 iCV40 RCBO 1P+N C 16 A 30mA ASI

The Schneider Electric Acti9 iCV40 1P+N C 16 A 30mA ASI RCBO is a comprehensive solution offering protection against both overcurrents and earth leakage. With a nominal current of 16 A and a C tripping curve, it is designed to protect electrical installations in residential and commercial environments, providing safety against overloads, short circuits, and electric shock hazards.

This device is ideal for single-phase circuits, as it includes a protected pole and A-SI type differential protection, with a sensitivity of 30 mA that acts instantaneously. This type of protection detects both alternating currents and pulsating direct currents, ensuring effective protection against potential electrical leaks that could endanger people or cause fires.

The Acti9 iCV40 is designed with a breaking capacity of 6000 A at 230 VAC, complying with stringent international safety standards (EN/IEC 61009-2-1). This RCBO switch also offers the advantage of two exclusive VisiTrip visual indicators, allowing for quick identification of the faulty circuit and type of fault, significantly reducing intervention and repair time. Additionally, its green VisiSafe band guarantees the physical opening of contacts, allowing for safe downstream system maintenance.

Key Features:

  • Nominal current: 16 A
  • Differential sensitivity: 30 mA
  • Tripping curve: Type C (5-10 x In)
  • Earth leakage protection class: Type A-SI (instantaneous sensitivity)
  • Short-circuit breaking capacity: 6000 A at 230 VAC
  • Protection: Short circuits, overloads, earth leakages, and fire hazards

This differential switch features thermal-magnetic technology that ensures fast and effective protection. Thermal protection activates in the event of prolonged overloads, while magnetic protection responds to short circuits, ensuring a quick disconnection to prevent damage to the installation. Moreover, it can operate in networks with a frequency of 50/60 Hz, and its operating voltage is 230 VAC.

The Acti9 iCV40 boasts outstanding mechanical and electrical durability, with up to 20,000 operating cycles, ensuring long life and reliability over time. It also has an IP20 protection rating (or IP40 when installed in modular enclosures), ensuring the device is resistant to unauthorised handling and dust.

Key Technical Data:

  • Nominal operating voltage: 230 VAC
  • Nominal insulation voltage (Ui): 400 VAC
  • Impulse withstand voltage (Uimp): 4 kV
  • Frequency: 50/60 Hz
  • Breaking capacity: 6000 A according to IEC 61009-2-1
  • Mechanical durability: 20,000 cycles
  • Electrical durability: 20,000 cycles
  • Dimensions: 36 mm wide, 85 mm high, 73 mm deep
  • Weight: 210 g

Additional Features:

This RCBO switch is also equipped with an ergonomic control handle that allows for easy manual operation, plus visual indicators that show the on/off status and the presence of faults in the circuit. The installation is quick and easy thanks to its adjustable clip system, compatible with standard DIN rails, facilitating its integration into modular electrical panels.

The tunnel-type terminals allow for reliable and secure connections, accommodating rigid cables up to 16 mm² and flexible cables up to 10 mm², providing flexibility during installation. Additionally, the device offers padlock locking options to prevent unauthorised tampering.

Additional Benefits:

  • Enhanced safety: The VisiSafe function ensures the switch is physically disconnected before proceeding with maintenance tasks, increasing safety for operators.
  • Quick diagnosis: VisiTrip indicators provide clear information on the circuit status, facilitating quick identification and resolution of problems.
  • Comprehensive protection: This switch not only protects against overcurrents but also ensures protection against earth leakages, contributing to the electrical safety of installations.

In conclusion, the Schneider Electric Acti9 iCV40 is an excellent choice for those seeking an efficient and safe solution to protect their electrical installations. With its ability to combine protection against overloads, short circuits, and earth leakages, along with its durability and advanced diagnostic features, this device ensures safety and optimal performance in residential and commercial environments.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9DF3616
SKU
SCH5BAF1C81
Object
Circuit breaker
Number of poles
1P+N, 1P + N
Assembly
DIN rail. Clip adjustable.
Nominal current
16 A
Network type
AC
Protection rating
IP20
Frequency
50/60 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
VisaMastercardPayPalKlarnaBank transfer
All rights reserved © 2025 GroupSumi