Resettable Differential Gewiss RESTART RD 2P 40A 30mA Class A with reference GWD4827R from the brand GEWISS
Resettable Differential Gewiss RESTART RD 2P 40A 30mA Class A with reference GWD4827R from the brand GEWISS
GEWISS

Resettable Differential Gewiss RESTART RD 2P 40A 30mA Class A

REF
GWD4827R
(0)
+101
124.00 €
€124.00
€354.24
If you are a professional, you have an exclusive price. Discover it.
The Gewiss RESTART RD 2P 40A 30mA Class A resettable circuit breaker provides protection and automatic reset after a trip, ensuring service continuity. With an Autotest function for automatic control without interruptions.
  • Automatic reset after trip
  • Rated current: 40A, 30mA Class A
  • Autotest function and differential protection
Buy now and receive it between 4 and 7 April
Express delivery
More about the product

Information about Resettable Differential Gewiss RESTART RD 2P 40A 30mA Class A

The Gewiss RESTART RD 2P 40A 30mA Class A Resettable RCD (reference GWD4827R) is an advanced solution for ensuring the protection of electrical installations, providing not only safety against current leaks but also service continuity thanks to its automatic reset system. This device is designed to restore the electrical supply after an unexpected trip, once it has verified the safety of the installation, thus preventing prolonged interruptions in the power supply and improving reliability in residential and commercial environments.

Main Features:

  • Automatic Reset: In the event that the residual current device trips due to a current leak, the ReStart system automatically checks the status of the installation. If it is confirmed that the conditions are safe, the device automatically restores the power supply, ensuring service continuity without the need for manual intervention.
  • Autotest Function: The Gewiss RESTART RD features an Autotest function that automatically and periodically verifies the correct operation of the RCD, all without interrupting the power supply. This system ensures that the device is always in optimal working condition, providing peace of mind to the user and eliminating the need for periodic manual testing.
  • Class A Differential Protection: Designed with Class A differential protection technology, the device is capable of detecting alternating current (AC) leaks as well as pulsed direct current (DC) leaks, making it ideal for applications involving electronic equipment such as computers, modern appliances, or LED lighting systems.

Safety and Performance:

  • Nominal Differential Current: The device is configured to detect differential currents from 30 mA, offering effective protection against electric shocks from indirect contact and minimising the risk of fires caused by current leaks.
  • Nominal Current of 40 A: With a nominal current of 40 A, this RCD is suitable for medium-sized installations typical in homes, offices, or small businesses.
  • Standards and Certification: The Gewiss RESTART RD complies with the EN 50557 standard, ensuring adherence to the highest safety and efficiency standards in electrical installation protection. It is also designed to be compatible with TT and TN-S distribution systems.

Key Technical Specifications:

  • Nominal AC Voltage: 230 V, compatible with most residential and commercial electrical networks in Europe.
  • Number of Poles: 2P, ensuring protection both in the phase and the neutral of the installation.
  • Nominal Frequency: 50-60 Hz, suitable for power supply in much of the world.
  • Insulation Voltage (Ui): 500 V, ensuring high resistance capacity against voltage spikes.
  • Surge Withstand Capacity: With a capacity of 4 kV, the device can withstand transient overvoltages without compromising functionality.
  • Nominal Resistance between Live Points and Earth: 16 kΩ, ensuring reliable operation in the event of leakage.
  • Overvoltage Category: III, guaranteeing robustness against adverse conditions in low-voltage installations.

Additional Functions:

  • Earth Leakage Test: The device performs an automatic earth leakage test to ensure the system does not present issues before resetting after a trip.
  • Reset of Unexpected Trips: The RCD is designed to automatically reset after unexpected trips, always verifying the safety of the installation before restoring the power supply.
  • Mechanical Resistance: With the ability to withstand up to 4000 mechanical operations, the device is built to last and resist wear associated with frequent use.

Applications and Benefits:

  • Residential and Commercial Installations: The Gewiss RESTART RD 2P 40A 30mA is ideal for ensuring electrical protection in homes, offices, shops, and small businesses. Thanks to its automatic reset capability, it is especially useful in situations where service continuity is crucial, such as in refrigerators, heating systems, computers, or servers.
  • Enhanced Safety: The device ensures that the electrical installation remains safe at all times by performing automatic checks before restoring power after a trip. Additionally, the Autotest function ensures that the RCD is always in perfect working order.
  • Easy Installation: With a 3-module format and a compact design, the resettable RCD is easy to install in electrical panels, occupying minimal space and providing an advanced protection solution without complications.
Specifications
Manufacturer
GEWISS
Reference
GWD4827R
SKU
GEW714572C7
Object
Reset device
Number of poles
2P
Nominal current
40 A
Protection rating
IP20
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
VisaMastercardPayPalKlarnaBank transfer
All rights reserved © 2025 GroupSumi